Handheld Wireless Vet Pulse Oximeter , 1.8" Color OLED Display 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: CMS60D


 
Handheld Wireless Vet Pulse Oxi

 

Handheld Wireless Vet Pulse Oximeter , 1.8" Color OLED Display

 

Quick Detail:

Principle of the CMS60D-Vet Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,The Veterinary Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through animal's tongue or ear and so on.The product is suitable for being used in family,pet hospital and etc. (It is recommended to use the device when the animal is still.

Description:

Small in volume light in weight and convenient in carrying
Operation of the product is simple ,low power consumption
Operation menu for the function setting
SpO2 value display
Pulse rate value display, bar graph display
Pulse waveform display
Screen brightness can be changed
Pulse rate sound indication
With review function
With clock function
With measured data overruns limits and low-voltage alarm function
Battery capacity indication
Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage ,and with alarm function
With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers
Real-time data can be transmitted to computers
Connected with an external oximeter probe
Wireless communication function CMS60DW-Vet



Specifications:

Display Mode 1.8" Color OLED display
Screen Resolution 160*128
SpO2 Measuring Range 0%°100%, (the resolution is 1%).
Accuracy 70%°100% ±2% ,Below 70% unspecified.
PR Measuring Range 30bpm°250bpm, (the resolution is 1bpm)
Accuracy ±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Power Consumption less than 100mA
Voltage: DC 2.6V~3.6V
Power Supply: Dry battery(2AA)
Battery working hour: Theoretical number is 44 hours.
Safety Type:Interior Battery BF Type

 

bigPhoto
 Mr. Frank wang chao
manager
Tel: 86-311-68025728
Fax: 86-311-68025728
Mobile: 86- 133 6383 5500
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Hebei Aixuanda medical equipment Co.,Ltd [China (Mainland)]


Business Type:Manufacturer
City: Shijiazhuang
Province/State: Hebei
Country/Region: China (Mainland)

You May Like: