Post Offer Free
Hebei Aixuanda medical equipment Co.,Ltd  

Gold Index: 9897

You are here: home  > Medical Vacuum Pumps  > Automatic Medical Vacuum Pumps , Single Channel Syringe Pump

Automatic Medical Vacuum Pumps , Single Channel Syringe Pump 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: JAZ-6T


 
Automatic Medical Vacuum Pumps

 

Automatic Medical Vacuum Pumps , Single Channel Syringe Pump

 

Quick Detail:

 

174 Drugs with 10 Categories of Drug Library

 

 

Description:

 

Features:
1. Four working modes:
Rate mode, Time mode, Weight mode and Drug mode
2. 174 Drugs with 10 Categories of Drug Library
Cardiovascular Sys, Respiratory Sys, Antibiotics Sys, Alimentary Sys.
Nervous Sys, Analgesic Sys, Urinary Sys, Blood Sys, Endocrine Sys.
17 units of dose: Ug/kg/min, mg/kg/min, g/kg/min, ug/kg/h, mg/kg/h, g/kg/h, ug/min, mg/min, g/min, ug/h, mg/h, g/h, U/min, IU/h, U/kg/h, ng/kg/min, can make drug dispensing more convenient and safer.
3. ICU infusion workstation: Combines for syringe pumps and one infusion
Pump with Infusion Support into one ICU Infusion Workstation, sharing a Power Interface.
4. Stackable up to the maximum 8 channels. Transfer the message between the Nurse-call System and the pumps.
5. Bolus Function.

 

 

Specifications:
 

1. Compatible Syringe: Any standard syringe with 5ml, 10ml, 20ml, 30ml, 50ml and 60ml.
2. Accuracy: ± 2% (Any manufacturers of syringes, right after calibration)
Delivery rate range:
50 ml syringe - 0.1 1800 ml / hr (0.1 ml / hr step)
30 ml syringe - 0.1 1200 ml / hr (0.1 ml / hr step)
20 ml syringe - 0.1 800 ml / hr (0.1 ml / hr step)
10 ml syringe - 0.1 400 ml / hr (0.1 ml / hr step)
5 ml syringe - 0.1 200 ml / hr (0.1 ml / hr step)
3. Time setting mode range:
Volume: 0.1 999.9ml, 0.1ml step.
Time: 0.1 999.9min, 0.1min step.
4. Drug Library setting mode range:
Sol. Volume: 0.1 199.9ml, 0.1ml step.
Drug mass: 0.1 999.9ml, 0.1 ml step.
Dose: 0.001 9999, 0.001 step.
5. Bolus setting mode range:
Bolus. Volume: 0.1ml 60.0ml, 0.1ml step
Bolus Rate: 5ml: 0.1ml/h 200.0ml/h, 0.1ml/h step
10ml: 0.1ml/h 400.0ml/h, 0.1ml/h step
20ml: 0.1ml/h 800.0ml/h, 0.1ml/h step
30ml: 0.1ml/h 1200.0ml/h, 0.1ml/h step
50ml(60ml): 0.1ml/h 1800.0ml/h, 0.1ml/h step
6. Purge 50ml(60ml): 1800.0ml/h, 20ml(30ml); 800.0ml/h
10ml: 400.0ml/h
5ml: 200.0ml/h
7. KVO rate: 0.1ml/h-1.0ml/h, 0.1ml/h step
8. Alarms: Near empty, Syringe empty, Volume complete (a volume limit has been set), Occlusion, Syringe loss, Syringe dislocated, Operation error, Low battery and other device failures.
9. Power supply: AC 100-240V +/- 10%, 50/60Hz. 10. Power consumption: 25<=VA
10. Internal Lithium Battery: 11.1V, 2000mAh, Approximately 8 hours of continuous operation in a new and fully charged battery running at 5ml/h.
11. Safety level: Class I, Type: CF
12. Size: 230mm(L) x 150mm(W) x 125mm(H)
13. Net Weight: 2.2Kg. (Approx)
14. Operating conditions:
Ambient temperature: 5-40° C Relative humidity: 20 to 90%
15. Storage conditions:
Ambient temperature: -10-55° C Relative humidity: 10 to 90%
16. Accessories: AC power line, Operational manual

 

bigPhoto
 Mr. Frank wang chao
manager
Tel: 86-311-68025728
Fax: 86-311-68025728
Mobile: 86- 133 6383 5500
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Hebei Aixuanda medical equipment Co.,Ltd [China (Mainland)]


Business Type:Manufacturer
City: Shijiazhuang
Province/State: Hebei
Country/Region: China (Mainland)

You May Like:

syringe pump(JAZ-6T)
The specification of syringe pump  
Flow rate 0.1ml/h-1500ml/h(0.1ml/h increments, 1ml/h increments when rate is over 1000ml/h )50ml syringe
0.1ml/h-900ml/h      (0.1ml/h increments)30ml syringe
0.1ml/h-600ml/h(0.1ml/h increments)20ml syringe
0.1ml/h-400ml/h(0.1ml/h increments)10ml syringe
Bolus rate 1500ml/h(50 syringe); 900ml/h(30ml syringe); 600ml/h(20ml syringe); 400ml/h(10ml)
Occlusion pressure 40N, 60N(± 10N)
Volumetric accuracy ≤ 2%(drive accuracy ≤ 1%)
Total volume indication 0.1-9999ml
Preset limited volume 0.1-9999ml
Alarm Near empty, Empty, Syringe dislocated, Syringe plunger disengaged, Malfunction, Forget to operate after power on, Occlusion, Low battery, Battery volume exhausted, AC power failure, Preset limited volume is finished
Operating condition Temperature: -40 to 40degree; Relative humdity: 20 to 90%
Transport and Temperature: -40 to 55degree
storage condition
External dimensions 306(L)× 135(W) × 127(H)mm
Net weight