Hebei Aixuanda medical equipment Co.,Ltd
|
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Medical Portable Electric Smart Infusion Pump With Drug Library
Quick Detail:
Can be used for all standards of sterile burette type infusion set for single use
Description:
Can be used for all standards of sterile burette type infusion set for single use (Correspond ISO 8536-4: 2007 standard).
Automatic Calibration for IV sets.
Five working modes: Rate mode, Time mode, Volumetric mode, Dose mode and Drug library mode.
Built in rechargeable battery (Lithium-ion polymer battery).
Spec of the fuse: F1AL/250V, two (inside).
8 hours internal battery backup.
Alarm functions: Occlusion, empty bottle, low battery, rate error, end of infusion, door open, air in line etc
Three levels of the occlusion limited pressure: High, middle and low.
Three levels of alarm sound: High, middle and low.
The infusion pump goes into KVO mode automatically as infusion is completed.
Purge and Bolus functions
Anti-bolus function
History records being demanded directly. And with RS232 ports as well, in order to connect other equipments.
Waterproof class: IPX4
Technical Specification:
Flow range: 1.0~99.9ml/h, 0.1ml/h increment
100~1200ml/h, 1ml/h increment
Or 1~400drops/min, 1 drop/min increment.
Flow precision: ± 5%
Target volume (TAR VOL): 0.1~99.9ml, 0.1 ml increment; 100~9999 ml, 1ml increment.
Infusion time (TIME): 1min~6000min, increment 1min.
Adjustable range of infusion precision: -50%~+50%, increment: 1% (for volumetric mode).
Infused Volume range: 0.1~99.9ml increment 0.1ml; 100~9999ml, 1ml increment.
Adjustable ranges of Sol. Vol, Drug Mass, Dose:
Sol. Vol (solution Volume): 1~9999 ml, increment: 1ml
Drug Mass: 0.1~999.9, increment: 0.1, Unit: G, mg, U, IU;
Dose: 0.001~9.999, increment: 0.001; 10.00~99.99, increment: 0.01;
100.0~999.9, increment 0.1; 1000~9999, increment 1;
Dose units: Ng/kg/min; Ug/kg/min; Mg/kg/min; G/kg/min; Ug/kg/h; Mg/kg/h; G/kg/h;
Ug/min; Mg/min; G/min; Ug/h; Mg/h; G/h; U/min; U/h; IU/h; U/kg/h; Mg/kg; Ml/min; Ml/h;
Body Weight range: 0.1~300.0kg, increment: 0.1kg
Purge: 600 ml/h.
Bolus: Adjustable from 1~1200ml/h, in steps of 0.1ml/h (if flow rate < 100ml/h) and 1ml/h (if flow rate > 100ml/h), Target Volume: 1~500 ml, in steps of 1ml
KVO rate: If the flow rate ≤ 10 ml/h, KVO is 1ml/h.
Otherwise KVO is 3ml/h.
Power supply: AC100~240V, 50/60Hz, Internal Lithium-ion polymer battery: DC 11.1V, ≥ 1600mAh. The battery backup is approx. 8 hours (when using a fully charged battery and running at 20drops/min with any standard IV Set).
Power consumption: ≤ 25VA
Class: I
Type: CF
Size: 125mm(W)× 230mm(H)× 125mm(D)
Net weight: Approx. 2kg
Operating condition:
Ambient temperature: 5~40 degree C,
Relative humidity: 20~90%
Storage condition:
Ambient temperature: -10~55 degree C
Relative humidity: 10~90%.
Competitive Advantage:
Our company research and development with independent intellectual property rights of Infusion pump , technology mature and stable, easy operation, high cost performance, etc. It is through the Chinese many hospitals more than 10 years of clinical tests, get professional certification agency inspection of quality product. Our products sell very good in the international market, please choose to cooperate with us, this is your wise choice. We will use high-quality products, excellent service to prove your wise choice.